Newsflash

My dearest friends, Please I am taking this opportunity to praise the relationship between you and Mosopower for ten years. Under your support, Mosopower group is growing in steady; and now is becoming one of the leaders in power industry.
 
Sign up for PayPal and start accepting credit card payments instantly. 8 kB

Featured Products

90W Switching Power Supply -AC/DC SMPS Adapter -Desktop
90W Switching Power Supply -AC/DC SMPS Adapter -Desktop
200W Switching Power Supply -AC/DC SMPS Adapter -Desktop
200W Switching Power Supply -AC/DC SMPS Adapter -Desktop
180W Switching Power Supply | AC/DC SMPS | Open Frame
180W Switching Power Supply | AC/DC SMPS | Open Frame
120W Switching Power Supply -AC/DC SMPS Adapter -Desktop
120W Switching Power Supply -AC/DC SMPS Adapter -Desktop

Random Products

EI-48 Linear Power Supply | AC/AC AC/DC Linear Adapter
EI-48 Linear Power Supply | AC/AC AC/DC Linear Adapter
EI-35 Linear Power Supply | AC/AC AC/DC Linear Adapter
EI-35 Linear Power Supply | AC/AC AC/DC Linear Adapter
48W Switching Power Supply -AC/DC SMPS Adapter -Desktop
48W Switching Power Supply -AC/DC SMPS Adapter -Desktop
18W Switching Power Supply -AC/DC SMPS Adapter -Desktop
18W Switching Power Supply -AC/DC SMPS Adapter -Desktop

Home arrow Power Supply Blog arrow Switching Power Supply Current-Limit Latchup(4 of 6)

Switching Power Supply Current-Limit Latchup(4 of 6)

Solution

  • Start-up into no load or a reduced load. The dotted orange lines in Figure 1 show how reducing the load (less input power) moves the power hyperbola in so that it clears the source V-I characteristics. Load shedding is often used in space-craft solar-array powered systems to shift from the undesired stable point to the desired stable point if latchup occurs.
  • Prevent operation at low input voltages. Inhibiting switching-action until a preset minimum voltage is reached shifts the "resistive" part of the turn-on trajectory in Figure 1 up to help clear the source V-I characteristic. There is also another compelling reason (future topic) to do this. Hysteresis should be added so the supply turns on at a higher voltage than it turns off. This prevents on/off oscillations for slow turn-on or when the input voltage remains near the turn-on point.
  • Extend or remove the current limit during start-up. This solution is not available for inherently current-limited sources such as solar arrays but is a common solution for systems whose source characteristics are controlled by feedback loops. In Figure 1 this is illustrated by starting with current limit set at the solid blue line, letting the desired operating point be reached (green circle), and then pulling the current limit into the desired steady-state current limit(dotted blue line). The disadvantage is that the system is unprotected at start-up and a timing race is possible.
  • Limit the maximum duty cycle. This has the effect of increasing the slope of the "resistive" portion of the start-up trajectory. If done dynamically a timing race is possible and design tolerances may be a problem. This can be mitigated by adaptively modifying maximum duty cycle as a function of input voltage.

Do not use this information for design without independent verification of the information.

Editor: Jerrold Foutz

 
< Prev   Next >

Product Scroller

90W Desktop Switching Power Supply
90W Desktop Switching Power Supply


EI-57 Linear Power Supply | AC/AC AC/DC Linear Adapter
EI-57 Linear Power Supply | AC/AC AC/DC Linear Adapter


EI-35 Linear Power Supply | AC/AC AC/DC Linear Adapter
EI-35 Linear Power Supply | AC/AC AC/DC Linear Adapter


17W Switching Power Supply | AC/DC SMPS | Open Frame
17W Switching Power Supply | AC/DC SMPS | Open Frame


9.68W Switching Power Supply | AC/DC SMPS | Open Frame
9.68W Switching Power Supply | AC/DC SMPS | Open Frame


18W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount
18W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount


100/120w Desktop Switching Power Supply
100/120w Desktop Switching Power Supply


42W Switching Power Supply | AC/DC SMPS | Open Frame
42W Switching Power Supply | AC/DC SMPS | Open Frame


Car Charger | Switch-mode Car Charger
Car Charger | Switch-mode Car Charger


Led Power Supply
Led Power Supply


72W Desktop Switching Power Supply
72W Desktop Switching Power Supply


200W Switching Power Supply -AC/DC SMPS Adapter -Desktop
200W Switching Power Supply -AC/DC SMPS Adapter -Desktop


24W Switching Power Supply -AC/DC SMPS Adapter -Desktop
24W Switching Power Supply -AC/DC SMPS Adapter -Desktop


3W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount
3W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount


160W Switching Power Supply -AC/DC SMPS Adapter -Desktop
160W Switching Power Supply -AC/DC SMPS Adapter -Desktop


12W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount
12W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount


Intelligent Charger | Switch-mode Charger
Intelligent Charger | Switch-mode  Charger


8.5W Switching Power Supply | AC/DC SMPS | Open Frame
8.5W Switching Power Supply | AC/DC SMPS | Open Frame


Webbieworld SiteWars

Webbieworld Voting

Latest products

180/220/300W Desktop Switching Power Supply
180/220/300W Desktop Switching Power Supply
 Email for Pricing
150w Desktop Switching Power Supply
150w Desktop Switching Power Supply
 Email for Pricing
100/120w Desktop Switching Power Supply
100/120w Desktop Switching Power Supply
 Email for Pricing
90W Desktop Switching Power Supply
90W Desktop Switching Power Supply
 Email for Pricing
72W Desktop Switching Power Supply
72W Desktop Switching Power Supply
 Email for Pricing
Led Power Supply
Led Power Supply
 Email for Pricing
180W Switching Power Supply | AC/DC SMPS | Open Frame
180W Switching Power Supply | AC/DC SMPS | Open Frame
 Email for Pricing
© 2008 Switching Power Supply(SMPS)-MOSO: Manufacturer&Supplier Specialized In Switching Power Supply.
Original Site Design by new-loong
stats