Newsflash

My dearest friends, Please I am taking this opportunity to praise the relationship between you and Mosopower for ten years. Under your support, Mosopower group is growing in steady; and now is becoming one of the leaders in power industry.
 
Sign up for PayPal and start accepting credit card payments instantly. 8 kB

Featured Products

180W Switching Power Supply | AC/DC SMPS | Open Frame
180W Switching Power Supply | AC/DC SMPS | Open Frame
Led Street light Power Supply
Led Street light Power Supply
72W Desktop Switching Power Supply
72W Desktop Switching Power Supply
Led Tunnel Light Power Supply
Led Tunnel Light Power Supply

Random Products

Cargador del coche
Cargador del coche
90W Switching Power Supply -AC/DC SMPS Adapter -Desktop
90W Switching Power Supply -AC/DC SMPS Adapter -Desktop
24W Switching Power Supply -AC/DC SMPS Adapter -Desktop
24W Switching Power Supply -AC/DC SMPS Adapter -Desktop
17W Switching Power Supply | AC/DC SMPS | Open Frame
17W Switching Power Supply | AC/DC SMPS | Open Frame

Home arrow Power Supply Blog arrow Switching Power Supply Current-Limit Latchup(4 of 6)

Switching Power Supply Current-Limit Latchup(4 of 6)

Solution

  • Start-up into no load or a reduced load. The dotted orange lines in Figure 1 show how reducing the load (less input power) moves the power hyperbola in so that it clears the source V-I characteristics. Load shedding is often used in space-craft solar-array powered systems to shift from the undesired stable point to the desired stable point if latchup occurs.
  • Prevent operation at low input voltages. Inhibiting switching-action until a preset minimum voltage is reached shifts the "resistive" part of the turn-on trajectory in Figure 1 up to help clear the source V-I characteristic. There is also another compelling reason (future topic) to do this. Hysteresis should be added so the supply turns on at a higher voltage than it turns off. This prevents on/off oscillations for slow turn-on or when the input voltage remains near the turn-on point.
  • Extend or remove the current limit during start-up. This solution is not available for inherently current-limited sources such as solar arrays but is a common solution for systems whose source characteristics are controlled by feedback loops. In Figure 1 this is illustrated by starting with current limit set at the solid blue line, letting the desired operating point be reached (green circle), and then pulling the current limit into the desired steady-state current limit(dotted blue line). The disadvantage is that the system is unprotected at start-up and a timing race is possible.
  • Limit the maximum duty cycle. This has the effect of increasing the slope of the "resistive" portion of the start-up trajectory. If done dynamically a timing race is possible and design tolerances may be a problem. This can be mitigated by adaptively modifying maximum duty cycle as a function of input voltage.

Do not use this information for design without independent verification of the information.

Editor: Jerrold Foutz

 
< Anterior   Siguiente >

Product Scroller

Cargador del coche
Cargador del coche


Transformador EI
Transformador EI


Adaptador CA/CA CA/CC EI-35
Adaptador CA/CA CA/CC EI-35


150w Desktop Switching Power Supply
150w Desktop Switching Power Supply


72W Desktop Switching Power Supply
72W Desktop Switching Power Supply


180W Switching Power Supply | AC/DC SMPS | Open Frame
180W Switching Power Supply | AC/DC SMPS | Open Frame


60W Switching Power Supply -AC/DC SMPS Adapter -Desktop
60W Switching Power Supply -AC/DC SMPS Adapter -Desktop


adaptador del tablero del escritorio 200W
adaptador del tablero del escritorio 200W


8.5W Switching Power Supply | AC/DC SMPS | Open Frame
8.5W Switching Power Supply | AC/DC SMPS | Open Frame


100/120w Desktop Switching Power Supply
100/120w Desktop Switching Power Supply


8-100W Abra las fuentes de alimentación del marco
8-100W Abra las fuentes de alimentación del marco


Adaptador-módulo tablero del escritorio 12W
Adaptador-módulo tablero del escritorio 12W


Adaptador-módulo Plug-in 5W
Adaptador-módulo Plug-in 5W


Led Tunnel Light Power Supply
Led Tunnel Light Power Supply


36W Switching Power Supply -AC/DC SMPS Adapter -Desktop
36W Switching Power Supply -AC/DC SMPS Adapter -Desktop


3W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount
3W Switching Power Supply -AC/DC SMPS Adapter -Wall-Mount


Adaptador CA/CA CA/CC EI-41
Adaptador CA/CA CA/CC EI-41


90W Desktop Switching Power Supply
90W Desktop Switching Power Supply


Webbieworld SiteWars

Webbieworld Voting

Latest products

Led Tunnel Light Power Supply
Led Tunnel Light Power Supply
 Llame para precio
Led Street light Power Supply
Led Street light Power Supply
 Llame para precio
180/220/300W Desktop Switching Power Supply
180/220/300W Desktop Switching Power Supply
 Llame para precio
150w Desktop Switching Power Supply
150w Desktop Switching Power Supply
 Llame para precio
100/120w Desktop Switching Power Supply
100/120w Desktop Switching Power Supply
 Llame para precio
90W Desktop Switching Power Supply
90W Desktop Switching Power Supply
 Llame para precio
72W Desktop Switching Power Supply
72W Desktop Switching Power Supply
 Llame para precio
© 2008 Switching Power Supply(SMPS)-MOSO: Manufacturer&Supplier Specialized In Switching Power Supply.
Original Site Design by new-loong
stats