• 简体
  • 繁體
  • Nederlands
  • English
  • Français
  • Deutsch
  • Italiano
  • 日本語
  • 한국어
  • Português
  • русском
  • Español
  • Svenska

新闻快讯

仰首是春,俯首是秋。2008年翩跹而至,也迎来了茂硕电源的十载耕耘。岁月如歌,春华秋实。我们已走过日新月异、不断开拓创新的十年,正是在您诚挚的关爱与支持下,我们取得了丰硕的成果。感谢您!
 
Sign up for PayPal and start accepting credit card payments instantly. 8 kB

特色产品

SMPS - 200W开关电源/交流转直流/桌面系列开关电源SMPS
SMPS - 200W开关电源/交流转直流/桌面系列开关电源SMPS
100/120W桌面适配器
100/120W桌面适配器
LED隧道灯电源
LED隧道灯电源
SMPS - 90W开关电源/交流转直流/桌面系列开关电源SMPS
SMPS - 90W开关电源/交流转直流/桌面系列开关电源SMPS

随机展示

SMPS - 8.5W多路裸板系列/交流转直流 | Open Frame SMPS
SMPS - 8.5W多路裸板系列/交流转直流 | Open Frame SMPS
SMPS - 5W开关电源/交流转直流/插墙系列立式、卧式SMPS
SMPS - 5W开关电源/交流转直流/插墙系列立式、卧式SMPS
15W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源
15W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源
12W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源
12W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源

首页 arrow 电源博客 arrow Switching Power Supply Solar-Array Latchup(1 of 4)

Switching Power Supply Solar-Array Latchup(1 of 4)

Problem

The solar-array power system lockups in the battery-discharge mode when there is sufficient energy to charge the battery.

The problem occurs in a Direct Energy Transfer (DET) system consisting of a solar array directly powering the system voltage bus. System voltage regulation is provided by a shunt regulator working against the solar-array impedance. A battery provides power when there is insufficient energy from the solar array and a battery charger charges the battery when the solar-array output exceeds that required by the load.

Lockup can occur during a dark-to-light transition of the solar-array power source. In space systems, this can occur during initial deployment at launch or each time there is an orbital transition from eclipse to sunlight. It can also occur on the transition back to solar-array power if a transient increase in load requires transient energy from the battery.

 Switching Power Supply DET System I-V Characteristics D
Figure 1: DET System I-V Characteristics

Figure 1 shows the state-plane of the system where I is the current in the inductance of the cable from the solar array (approximates the solar-array current) and V is the voltage across the bus capacitance (approximates bus voltage). Superimposed on the I-V state-plane are the input characteristic of a switching-mode power supply (red) and the output characteristic of a solar-array (blue). (Notice other discussions in this hypertext sometimes plot similar characteristics in the V-I plane instead of the I-V plane as shown here.)

A family of system trajectories can be plotted on this plane for practical values of system inductor current and capacitor voltage. The trajectories and isoclines are not plotted here, but are in the references. What these trajectories show is that point B is an unstable operating point on a separatrix that passes between operating points A and B (dotted black line). Point A is stable and a node (real) or a focus (complex), but not a desired operating point since it is on the turn-on resistive part of the load line before the switching-mode power supply load begins operation. The stability of point C, which is the voltage the system goes to if the regulating shunt regulator fails open, depends on the values of L and C. For practical values of L and C it is usually stable. The normal end-of-life full-load operating point, point R, is usually selected to be the peak power point, near the inflection point of the solar-array characteristic. This point is unstable but is stabilized by the shunt regulator which regulates to a voltage near the point R voltage.

Also not plotted in Figure 1 are the composite load lines in the various operating modes -- battery charging, shunt regulation, etc, and plots of the solar-array characteristics at various illumination levels.

If these were added to Figure 1, then the trajectories from sun to eclipse and eclipse to sun could be plotted along these load lines. When this is done (see references), there is no latchup possible on the sun to eclipse trajectories. However, when the battery is powering the load, the operating point is on the left-side of the separatrix (dotted black line through point B) and under some conditions can not get back to the desired right-side of the separatrix. This presents a controllability problem and results in latchup. The load continues to be partially powered by the battery, even if there is sufficient energy from the solar-array to power the load and charge the battery.

The discharge is usually small in tightly regulated bus systems but can be very large in semi-regulated bus systems.

Do not use this information for design without independent verification of the information.

Editor: Jerrold Foutz

 
< 上一篇   下一篇 >

滚动展示

100/120W桌面适配器
100/120W桌面适配器


18W开关电源 | 交流转直流开关电源 | 桌面系列开关电源
18W开关电源 | 交流转直流开关电源 | 桌面系列开关电源


36W开关电源 | 交流转直流开关电源 | 桌面系列开关电源
36W开关电源 | 交流转直流开关电源 | 桌面系列开关电源


EI-41 AC/AC AC/DC适配器
EI-41 AC/AC AC/DC适配器


24W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源
24W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源


EI-57 AC/AC AC/DC适配器
EI-57 AC/AC AC/DC适配器


24W开关电源 | 交流转直流开关电源 | 桌面系列开关电源
24W开关电源 | 交流转直流开关电源 | 桌面系列开关电源


15W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源
15W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源


EI变压器
EI变压器


LED路灯电源
LED路灯电源


72W桌面式适配器
72W桌面式适配器


18W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源
18W开关电源 | 交流转直流开关电源 | 插墙系列立式、卧式开关电源


90W 桌面适配器
90W 桌面适配器


SMPS - 9.68W多路裸板系列/交流转直流 | Open Frame SMPS
SMPS - 9.68W多路裸板系列/交流转直流 | Open Frame SMPS


180/220/300W桌面适配器
180/220/300W桌面适配器


智能充电器
智能充电器


LED隧道灯电源
LED隧道灯电源


SMPS - 90W开关电源/交流转直流/桌面系列开关电源SMPS
SMPS - 90W开关电源/交流转直流/桌面系列开关电源SMPS


Webbieworld SiteWars

Webbieworld Voting

最新产品

LED隧道灯电源
LED隧道灯电源
 Email询价
LED路灯电源
LED路灯电源
 Email询价
180/220/300W桌面适配器
180/220/300W桌面适配器
 Email询价
150W桌面适配器
150W桌面适配器
 Email询价
100/120W桌面适配器
100/120W桌面适配器
 Email询价
90W 桌面适配器
90W 桌面适配器
 Email询价
72W桌面式适配器
72W桌面式适配器
 Email询价
© 2008 Switching Power Supply(SMPS)-MOSO: Manufacturer&Supplier Specialized In Switching Power Supply.
Original Site Design by new-loong
stats