design a sense circuit for this voltage with hysteresis
use the circuit to inhibit turn-on until the proper voltages are reached
add soft start to minimize the load transient at turn-on
and then by means of simulation and lab measurements, check the transient stress on components during turn-on and turn-off, especially the V-I trajectories of semiconductor switches in relation to their safe-operating area
Do not use this information for design without independent verification of the information.